Filter Results By:

Products

Applications

Manufacturers

Showing results: 136 - 149 of 149 items found.

  • Coaxial Matrix Switch, DC to 20 GHz

    87606B - Keysight Technologies

    The Keysight 87606B matrix switch provides the life and reliability required for automated test and measurement, signal monitoring and routing applications. Innovative design and careful process control creates a switch that meets the requirements for highly repeatable switching elements in test instruments and switching interfaces. The switch is designed to operate for more than 10 million cycles and will meet all electrical specifications for at least 5 million cycles. The switch exhibits exceptional insertion loss repeatability. This reduces sources of random errors in the measurement path and improves measurement uncertainty. Switch life is a critical consideration in production test systems, satellite and antenna monitoring systems, and test instrumentation. The longevity of the switch increases system uptime, and lowers the cost of ownership by reducing calibration cycles and switch maintenance.

  • Multiport Coaxial Switch, DC to 20 GHz, SP4T

    87204B - Keysight Technologies

    The Keysight 87204B terminated multiport switch provides the life and reliability required for automated test and measurement, signal monitoring and routing applications. Innovative design and careful process control created the Keysight 87204B which meet the requirements for highly repeatable switching elements in test instruments and switching interfaces. The Keysight 87204B is designed to operate for more than 10 million cycles. The exceptional 0.03 dB insertion loss repeatability is warranted for 5 million cycles at 25° C. This reduces sources of random errors in the measurement path and improves measurement uncertainty. Switch life is a critical consideration in production test systems, satellite and antenna monitoring systems, and test instrumentation. The longevity of this switch increases system uptime, and lowers the cost of ownership by reducing calibration cycles and switch maintenance.

  • MXG X-Series Microwave Analog Signal Generator, 9 kHz to 40 GHz

    N5183B - Keysight Technologies

    Get a fast, compact (2U) alternative to the PSG in the lab, depot or fieldAddress demanding tests of radar modules & systems with near-PSG levels of spectral purityCompensate for system loss & drive high-power amplifiers: +19 dBm output power, -55 dBc harmonics & -68 dBc spurious @ 20 GHzReduce calibration time with switching speed 600 sSimulate narrowband chirps & radar antenna scans with up to five internal function generators that can be used with AM, FM, OM pulse modulation

  • Medium-size Reverberation Chamber

    E-Series - Emite Ingeniería SL. Ed

    The E medium-size multicavity Reverberation Chamber Series represents that state-of-the-art in reverberation chamber technology. The E-Series can make single measurements, batch tests, protocols or campaign tests for different frequency bands, different technologies and different channel models, running overnight without human intervention. Embedded frequency-, mode-, source- and platform-stirring in a double-shielded set of cavities allow Passive MIMO (Efficiency, Correlation, Diversity Gain, MIMO Capacity and others), Active MIMO OTA (TRP, TIS, TPUT, MTS, CQI, M2TxDT, RSRP, MCL and others) and Time-Domain MIMO (DL/UL TCP/UDP TPUT, RMS DS, STD, PL, CBW, Mute%, eNodeB, VDT-OTA) measurements up to 8x8 and 8DLCC to be performed for antennas and devices up to 50cm and 50kg ranging from 2G to 4G, covering all available cellular and wireless technologies to date, including wearables devices, sound acoustic mute, WLAN and W-IoT testing. There is no RC in the market more advanced than the E-Series.

  • Resonance Dip Meter

    NRM-2 - National RF, Inc

    National RF’s Resonance Dip Meter is a test instrument used to determine the resonant frequency of a tuned circuit or resonant network, such as an antenna system. In addition, the unit may function as an RF detector, or a secondary frequency source. The instrument is analogous to the older vacuum tube “grid dip meter,” once popular in every electronic laboratory or radio station. Unique to this updated version is a buffered output that may drive a digital frequency counter for exact measurement of resonant frequency, or connected to an oscilloscope to be used as an RF detector and waveform/modulation monitor.

  • Low PIM Coaxial Switch, DC to 20 GHz, Matrix

    87406Q - Keysight Technologies

    Low passive intermodulation (PIM) is crucial for applications where two or more transmitted signals share a common antenna or whenever the transmitter signal is too high or the receiver is sensitive to high intermodulation. The Keysight 87406Q is a low PIM matrix coaxial switch, operating from DC to 20 GHz, which can help to keep the system PIM level low. A guaranteed 0.03 dB insertion loss repeatability and 3 million cycles of operating life ensures signal integrity, improves testing efficiency and ultimately maximizes test throughput.

  • Low PIM Coaxial Switch, DC to 20 GHz, Matrix

    87606Q - Keysight Technologies

    Low passive intermodulation (PIM) is crucial for applications where two or more transmitted signals share a common antenna or whenever the transmitter signal is too high or the receiver is sensitive to high intermodulation. The Keysight 87606Q is a low PIM matrix coaxial switch, operating from DC to 20 GHz, which can help to keep the system PIM level low. A guaranteed 0.03 dB insertion loss repeatability and 3 million cycles of operating life ensures signal integrity, improves testing efficiency, and ultimately maximizes test throughput.

  • Signal Level Meter

    XR-3 - Applied Instruments, Inc.

    From satellite dish alignment, to UHF off-air antenna pointing, to cable TV MER measurements, the XR-3 is the meter for you! The XR-3 is the most capable meter offered by Applied Instruments. It's more durable than the popular Super Buddy meter, and has added features and performance. The XR-3's modular design with field swappable modules provides wide versatility to fit different measurement applications, including DBS satellite (i.e. Dish Network, DIRECTV, Bell TV, Shaw Direct), VSAT satellite (i.e. iDirect, Hughes Ku band, and more), VHF/UHF off-air (analog and ATSC digital), and CATV (QAM and analog). The XR-3 is great for installing and troubleshooting DISH SmartBox, Blonder Tongue, and other SMATV headend systems often used in hotels, multi-dwelling units, and institutional facilities. Modular Test Instrument. Satellite Finder. Installer Signal Meters. CATV Analyzer. Modules.

  • Power Monitoring Kit For SAR System Validation

    PMK - ART-Fi SAS

    Test labs have a daily requirement to ensure SAR measurements are highly accurate. SAR systems must be vigorously checked to ensure the measuring accuracy meets the system manufacturer uncertainty budget. The PMK features technologies usually found in more expensive equipment at an affordable price. The ability to measure the S11 parameter for dipoles and antennas while continuously monitoring their linear behaviour differentiates the PMK from other systems. The ART-Fi PMK is an all-in-one solution that requires only three connections to perform automatic, highly precise validations and verifications. The lack of moving parts also leads to improved durability and fewer bugs, faults, and workarounds.

  • RF Power Amplifiers

    Precision Milimeter Wave

    Microwave and millimeter wave power amplifiers offer a wide variety of frequency ranges, bandwidths, gain and power outputs. Power amplifiers are used to convert low power signals to high power signals in the device. These are typically used in the Tx chain to amplify the signal before it is sent out via an antenna signal.Example specification in test data will be. Frequency, Small Signal Gain (dB), Output P1dB (dBm), Output Saturated Power, Amplifier Bias, Heat Sink Fan Bias, Maximum RF Input Power.If you are looking for RF Power Amplifiers we have the production capabilities to meet your needs.

  • PXIe-5652, 6.6 GHz RF Analog Signal Generator

    781217-01 - NI

    PXIe, 6.6 GHz, PXI RF Analog Signal Generator—The PXIe‑5652 features continuous-wave generation capabilities with FM, 2‑FSK, or OOK modulation. It uses direct digital synthesis (DDS) for high-resolution frequency hopping or phase-continuous sweeping for fixture and device characterization applications. The PXIe‑5652 is ideal for clocking nonstandard sample rates, such as WCDMA signals at baseband or intermediate frequency (IF). With these versatile signal generators, you can perform analog and digital modulation through the onboard DDS circuit, which gives you frequency modulation and frequency-shift keying for applications such as bit error rate test, antenna testing, or even keyless entry. You can also perform amplitude modulation using on-off keying.

  • PXI-5652, 6.6 GHz RF Analog Signal Generator

    779670-02 - NI

    6.6 GHz PXI RF Analog Signal Generator—The PXI‑5652 features continuous-wave generation capabilities with FM, 2‑FSK, or OOK modulation. It uses direct digital synthesis (DDS) for high-resolution frequency hopping or phase-continuous sweeping for fixture and device characterization applications. The PXI‑5652 is ideal for clocking nonstandard sample rates, such as WCDMA signals at baseband or intermediate frequency (IF). With these versatile signal generators, you can perform analog and digital modulation through the onboard DDS circuit, which gives you frequency modulation and frequency-shift keying for applications such as bit error rate test, antenna testing, or even keyless entry. You can also perform amplitude modulation using on-off keying.

  • PXI-5651, 3.3 GHz RF Signal Generator

    779670-01 - NI

    3.3 GHz PXI RF Analog Signal Generator—The PXI‑5651 features continuous-wave generation capabilities with FM, 2‑FSK, or OOK modulation. It uses direct digital synthesis (DDS) for high-resolution frequency hopping or phase-continuous sweeping for fixture and device characterization applications. The PXI‑5651 is ideal for clocking nonstandard sample rates, such as WCDMA signals at baseband or intermediate frequency (IF). With these versatile signal generators, you can perform analog and digital modulation through the onboard DDS circuit, which gives you frequency modulation and frequency-shift keying for applications such as bit error rate test, antenna testing, or even keyless entry. You can also perform amplitude modulation using on-off keying.

  • Telemetry Transmitter for FM with up to 3 Bands

    LS-11-F - Lumistar Inc.

    The LS-11-F portable FM test transmitter is designed for checkout and troubleshooting of telemetry receiving systems operating with FM modulation. For applications with any of the ARTM modulations (Tier 0, Tier I, or Tier II), please refer to the LS-11-M Data Sheet. Complete ground stations including the antenna with LNA, RF down-converter, IF receiver, bit synchronizer, and PCM decommutator can be tested and bit error tests performed. The design allows secure links to be tested with an external encryptor. The Test Transmitter contains an internal PCM Data Simulator and Pseudorandom patterngenerator that operates in a BERT mode. The device provides simulated clock and data (without transmitter enabled) and accepts external data for modulating the internal transmitter. Complete setup can be achieved locally through the keypad and two-line LCD display or remotely through the USB Interface. Operational parameters include the PCM format parameter database information (frame sync patterns, wavewords, etc…), pre-modulation filter selection, transmitter carrier frequency, transmitter deviation, and output power level. Output power can be selected from approx. -60 to +5 dBm in 5 dB steps. The Test Transmitter contains a LiFePO4 Battery (Lithium Iron Phosphate), which provides higher energy density at ¼ the weight of legacy lead-acid batteries. The unit also provides an internal battery charger and will operate for up to twelve hours on battery power having received on a full charge.

Get Help